| Product conformity |
EN 13241 |
Confirm that the industrial, commercial, or garage door is covered by the applicable product requirements and declared performance characteristics. |
Declaration of Performance, technical file, product scope, and applicable test reports. |
European and international projects referencing European product standards. |
| Thermal insulation performance |
EN 12428; ISO 10077-2; ASTM C1363; NFRC 100 |
Check the complete door assembly U-value or thermal transmittance, including curtain or panels, guides, bottom bar, seals, and vision sections where applicable. |
Accredited laboratory report, calculation method, declared U-value, test dimensions, and boundary conditions. |
Energy-conscious warehouses, cold-chain facilities, factories, and regulated building projects. |
| Air permeability |
EN 12426 and EN 12427 |
Verify the classified air-leakage performance at the specified pressure range and confirm that the tested configuration matches the supplied door. |
Air-permeability test report, classification, test pressure, door size, and seal configuration. |
Climate-controlled facilities and buildings with strict energy or hygiene requirements. |
| Wind resistance |
EN 12424 and EN 12444 |
Confirm the wind-load class for the actual opening size, installation exposure, curtain material, guides, and structural supports. |
Wind-load test report, declared class, allowable dimensions, deflection limits, and installation drawings. |
Coastal, high-rise, exposed, and severe-weather locations. |
| Water penetration |
EN 12425 |
Review the water-penetration classification and confirm the drainage, threshold, side-guide, and head-seal design. |
Water-penetration test report, classification, tested door arrangement, and installation requirements. |
Rain-exposed loading bays, food facilities, parking areas, and exterior openings. |
| Fire-resistance or fire-door performance |
UL 10B; UL 10C; EN 1634-1; NFPA 80 |
Determine whether the requirement is fire protection, fire resistance, or smoke control, and verify the complete tested assembly and rating period. |
Listing or certification record, fire-test report, labeled components, approved hardware, and installation instructions. |
Industrial plants, warehouses, commercial buildings, and compartmentation openings. |
| Powered-door safety |
EN 12453; EN 12445; applicable local machinery and electrical safety rules |
Check crushing, shearing, impact, emergency release, control logic, presence sensing, edge protection, and safe closing-force limits. |
Safety assessment, force-measurement report, wiring diagrams, risk assessment, and commissioning checklist. |
Automatic doors used by employees, vehicles, pedestrians, or material-handling equipment. |
| Electrical and control equipment |
IEC 60204-1; IEC 60335-1 where applicable; local electrical codes |
Verify voltage, frequency, enclosure rating, grounding, disconnect requirements, motor protection, emergency stop, and compatibility with site controls. |
Electrical schematics, component ratings, control-panel documentation, conformity declaration, and factory test record. |
Projects with country-specific electrical approval or hazardous operating environments. |
| Ingress protection |
IEC 60529 |
Confirm the IP rating of control boxes, sensors, motors, and accessories rather than assuming that the rating applies to the complete door. |
IP test report or component certificate, installation orientation, cable-entry details, and maintenance requirements. |
Wet, dusty, washdown, outdoor, and high-humidity installations. |
| Materials and corrosion resistance |
ISO 12944; ISO 9227; ASTM B117 where specified |
Match coating system, substrate, fasteners, and corrosion category to the site environment; confirm that salt-spray results are not used as a direct substitute for field-life guarantees. |
Coating specification, coating thickness records, salt-spray report, material certificates, and maintenance plan. |
Marine, chemical, humid, industrial, and high-cleanliness environments. |
| Quality management |
ISO 9001 |
Check that the certificate covers the relevant design, manufacturing, assembly, or service activities and remains valid for the production site. |
Current certificate, certification scope, issuing body, validity dates, and manufacturing-site address. |
Useful for supplier qualification and repeat international purchasing. |
| Environmental management |
ISO 14001 |
Verify the certificate scope and whether environmental controls cover manufacturing operations, waste, energy use, and relevant legal obligations. |
Current certificate, scope, audit status, environmental policy, and applicable compliance records. |
Public procurement, ESG-led sourcing, and projects with environmental prequalification. |
| Documentation and traceability |
Applicable conformity-assessment and product-traceability requirements |
Ensure model numbers, serial numbers, revision levels, tested configurations, spare parts, and installation manuals are consistent across all documents. |
Technical datasheet, installation manual, maintenance schedule, parts list, serial-number system, and warranty terms. |
All international projects, especially multi-site deployments and regulated facilities. |